Hansen logo Choosing the correct foot valve

Hansen foot valve Use the following flow chart and technical specifications to determine the correct Foot Valve for your requirements
Foot Valve selection instructions

Step 1: Measure or calculate the capacity of your pump installation.

Step 2: Look at the chart for the valve(s) that cover the flow rate.

Step 3: For dirty water applications choose the largest valve that will be operating in the area shown               by the thicker line.

Example: If your pumping capacity is 400 l/min use a FV32 Foot Valve
Foot valve flow chart - 25 to 63 mm
 

Maximum Head Pressure: @ 20C

VALVE FV25 FV32 40 FV50 FV63
psi 235 235 235 235 235
Bar 16 16 16 16 16
kPa 1600 1600 1600 1600 1600

Vacuum required for initial flow:

VALVE FV25 FV32 FV40 FV50 FV63
psi -0.5 -0.5 -0.5 -0.5 -0.5
kPa -3.5 -3.5 -3.5 -3.5 -3.5

Vacuum required to fully open diaphragm:

VALVE FV25 FV32 FV40 FV50 FV63
psi -1.5 -1.5 -1.5 -1.5 -1.5
kPa -10.0 -10.0 -10.0 -10.0 -10.0

Minimum flow for self cleaning action:

VALVE FV25 FV32 FV40 FV50 FV63
l/min 110 210 300 460 600

Connection: female BSPT

VALVE FV25 FV32 FV40 FV50 FV63
Thread Size 1" 1 1/4" 1 1/2" 2" 2 1/2"

Dimensions: (mm)

VALVE FV25 FV32 FV40 FV50 FV63
Diameter 69 87 99 123 152
length 72 88 99 120 157
Installation: Valve will operate at any angle.
Head Loss: See chart above.
Maximum operating temperature: 60C ( Degrees Celsius)
Note: All references to gallons are in imperial gallons